Reset to default settings – Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual
Page 73
72
CHAPTER 4 • CLICK 104
Note
This parameter can also be changed using Click Supervisor.
Level 1 LEDs
Baud rate for bus 1
Baud rate for bus 2
Level 2 LEDs
Cancel and exit menu
9600 bps (default)
19200 bps
38400 bps
LED off
LED on
57600 bps
Table 8.6 – Front Panel Menu Baud Rate Settings
See the earlier Navigating through the Menu and the Menu Operation Example sections for
how to configure this parameter.
Reset to Default Settings
The final option that comes up in the menu is Reset to Default Settings. To select this func-
tion, release the mode switch when the red LED starts flashing.
Note
Resetting to default settings can also be done using Click Supervisor.
This function will restore all configuration settings to factory defaults, even those param-
eters not configured using the front panel menu: baud rate, channel input map, description
field, location field, and device ID.
Level 1 LEDs
Reset to Default Settings
Level 2 LEDs
Cancel and exit menu
LED off
LED on
Reset to default settings
Table 8.7 – Front Panel Menu Reset to Default Settings
- Click 421 (bluetooth to serial converter) (CLK-421) - User Guide Click 342 (lean managed ethernet switch) (CLK-342) - User Guide Click 341 (lean managed ethernet switch) (CLK-341) - User Guide Click 340 (lean managed ethernet switch) (CLK-340) - User Guide Click 331 (unmanaged ethernet switch) (CLK-331) - User Guide Click 330 (unmanaged ethernet switch) (CLK-330) - User Guide Click 304 (RS-232 to RS-485 converter) (CLK-304) - User Guide Click 305 (RS-232 to RS-485 converter) (CLK-305) - User Guide Click 301 (serial to ethernet converter) (CLK-301) - User Guide Click 100 (16 output contact closure) (CLK-100) - User Guide Click 104 (4-channel DIN rail contact closure) (CLK-104) - User Guide Click 110 (4-channel contact closure eurocard) (CLK-110) - User Guide Click 112 (detector rack card) (CLK-112) - User Guide Click 114 (detector rack card) (CLK-114) - User Guide Click 120 (screw terminal relay) (CLK-120) - User Guide Click 121 (spring cage relay) (CLK-121) - User Guide Click 200 (surge suppression) (CLK-200) - User Guide Click 201 (1 amp AC to DC converter) (CLK-201) - User Guide Click 202 (2 amp AC to DC converter) (CLK-202) - User Guide Click 203 (UPS and battery) (CLK-203) - User Guide Click 204 (4 amp AC to DC converter) (CLK-204) - User Guide Click 210 (AC circuit breaker) (CLK-210) - User Guide Click 211 (AC outlet) (CLK-211) - User Guide Click 221 (DC surge protector) (CLK-221) - User Guide Click 222 (system surge protector) (CLK-222) - User Guide Click 223 (dual-485 surge protector) (CLK-223) - User Guide Click 230 (AC surge protector) (CLK-230) - User Guide Click 250 (wireless surge protector) (CLK-250) - User Guide