beautypg.com

On-device configuration, Configuration features, Autobaud (green solid) – Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual

Page 210

background image

CHAPTER 24 • CLICK 304 209

Configuration Features

The faceplate of the Click 304 has the following three LEDs:

˽

PWR (red) lights up when the device has power.

˽

TD (yellow) lights up when the device is transmitting data.

˽

RD (green) lights up when the device is receiving data.

The LEDs are also used to indicate operation modes, which will be discussed in the On-

device Configuration section of this chapter.

The front also has a push-button labeled Mode Switch, which is used to cycle the Click 304

through operation modes. This will be discussed in the On-device Configuration section

of this chapter.

On-device Configuration

The Click 304 can be configured using the push-button on the lower part of the faceplate.

Press and hold the push-button to cycle through the different operation modes; release the

button when the desired mode is reached. A quick press and release of the push-button will

exit out of any mode and return the unit back to normal operation. Table 24.1 and the fol-

lowing sections describe the different operating modes.

Mode

LED

Definition

Autobaud

Green (solid)

To autobaud the Click 304, press the push-button, then
release when the green LED turns on.

Reset

Red (flashing)

To reset the Click 304 to factory defaults, press the push-
button, then release when the red LED is blinking.

Table 24.1 – Click 304 Operation Mode Definitions

Autobaud (green solid)

The Autobaud mode is used to match baud rates with an external device. By default, the

device will attempt to match baud rates with a SmartSensor on the bus; however, the device

can be configured to autobaud with any device that supports a serial interface.

While the device is autobauding, the green LED will be on while the red LED blinks. The

autobaud was successful if the red LED stays on and the green LED turns off. If the auto-

baud is not successful after a few minutes of trying, the red and green LEDs will stay on

indefinitely. In the case of a failed autobaud, push the push-button once to return the device

to its normal state.

This manual is related to the following products: