Channel input map – Wavetronix Click 400 (900 MHz radio) (CLK-400) - User Guide User Manual

Page 114

background image

CHAPTER 10 • CLICK 112/114

113

˽

Bus 2 baud rate

˽

Channel input map

For each parameter, if any individual switch is in the ON position, that parameter is in

Hardware mode. If Hardware mode is selected, the parameter can be configured using the

switches. In this case, the setting can be viewed but not changed via Click Supervisor and

the front panel menu.

If all switches for a particular parameter are in the OFF position, that parameter is in Soft-

ware mode. If Software mode is selected, the parameter must be configured using the front

panel menu or Click Supervisor.

Channel Input Map

The first parameter that can be configured is channel input. Mapping input datagram chan-

nels to output channels is configured on the first DIP switch, labeled S4, using switches 1–4

(S4:1–4).

Note

If set to software mode, this parameter can also be changed using the front panel
menu or Click Supervisor.

As mentioned earlier, the Click 112//114 receives serial datagrams from a SmartSensor to

which is it connected. These datagrams can contain many channels of detection data.

Because the devices have fewer output channels than there are possible input datagram

channels received from the sensor, you must use the channel input map to map the desired

inputs to outputs. The Click 112 has two outputs and therefore must be mapped to two in-

puts; the Click 114 has four. (If you need more than two or four channels, you’ll need to use

multiple devices daisy-chained together.)

As shown in the table below, the outputs are mapped sequentially—that is, they can only be

mapped in numerically ordered groups of two or four depending on which device you are

using (1–2, 3–4, or 1–4, 5–8, etc.). If you chose, for example, 17–20 (on a Click 114), then

input 17 would be mapped to output 1, input 18 would be mapped to output 2, input 19

would be mapped to output 3, and input 20 would be mapped to output 4.

You will notice that the DIP switch labels on the Click 112 and 114 each have the input

mapping information for both devices combined. Make sure you are looking at the correct

information for your device. Additionally, the two sets of information are separated out and

displayed below. (To turn a switch on, flip it up. To turn a switch off, flip it down.)