Click 200 Lightning Surge

INSTALLER QUICK-REFERENCE GUIDE

www.wavetronix.com

801.734.7200

2

Wire power and communication

The Click 200 can take power and communications in through its screw terminals and send

it through any T-bus it is mounted on. To wire power through the Click 200: wire +DC from

the power supply into the screw terminal marked +DC on the PROTECTED side of the

Click 200. Wire -DC from the power supply into the screw terminal marked -DC.

Alternatively, power can be wired from the power supply into a 5-screw terminal block,

which can then be plugged into the left side of the T-bus. To wire power through the 5-screw

terminal block: wire +DC from the power supply into

the screw terminal marked +DC on the 5-screw terminal block. Wire

-DC from the power supply into the screw terminal marked -DC.

The front of the Click 200 has two communication ports (communica-

tion through the device’s screw terminals will be covered in Part 4).

˽

RJ-45 jack – A convenient way to connect RS-485 communications to a rack card

˽

DB-9 connector – Connect between here and your computer to configure your sensor

Note. Unlike on other Click devices, the RS-232 lines are not connected to the RS-485 lines on the Click

200. Be sure to test both lines as part of your installation process.

1

Mount the device

The Click 200 mounts over a T-bus for power and communication:
1 If the Click 200 was shipped with the T-bus connector attached, remove

the connector from the module.

2 Snap the connector onto the DIN rail by positioning it over the rail with

the male connector pointing to the right. Hook one arm over the edge of

the DIN rail and press down on the other arm until it snaps into place.

3 Connect the T-bus connector to the rest of the T-bus by sliding them

together until you hear them snap into place.

4 Mount the Click 200 onto the DIN rail: position it properly over the T-

bus connector, hook the lip over the lower edge of the DIN rail, and use a