Understand the device’s configuration features
The following physical features allow you to configure the Click 112/114:
˽
Mode Switch – Allows you to cycle through and select menu and configura-
tion options.
˽
Level 1 LEDs – Light up to indicate menu options while cycling through the
menu. They also have the following functions:
˿
Red – Lights up when the device has power
˿
Blue – Currently has no function
˿
Green – Lights up when the device is transmitting data
˿
Yellow – Lights up when the device is receiving data
˽
Level 2 LEDs – Light up to indicate configuration options. When the de-
vice is not in menu mode, these LEDs are off.
˽
Channel LEDs – The topmost bank of LEDs. These light up to indicate
vehicle detection.
˽
DIP Switches – Located on the lower part of the circuit board (left face of the board, if you’re looking at
the faceplate). These switches allow you to configure the device. This will be covered in greater detail in
Part 4.
www.wavetronix.com
801.734.7200
1
Mount and connect the device
Use the following steps to install the Click 112/114 rack cards:
1 If you’re using hardware configuration, set all DIP switches before
installing Click 112/114 devices (this will be covered in Part 4 of
this document).
2 Insert the cards into the rack.
3 Daisy-chain together all the cards in your installation, using short
RJ-11 jumper cables.
4 Connect the first Click 112/114 card to the SmartSensor via a Click
200 or Click 222 surge protector and a 60” RJ-11 patch cord.
Note. Bus 1 should be used to connect to the sensor, and bus 2 for configuration.
Channel
1
2
3
4
Menu
PWR PU TD RD
Level 1
Mode Switch
Level 2
1
2
3
4