CHAPTER 7 CLICK 101

Figure 7.7 – Expert Driver Autobaud Tab

Setting

Description

Command

Allows you to set the command sent from the device during the
autobaud process.

Response

Shows the response the device is expecting from the above command.

SmartSensor ID

Shows the ID number of one of the sensors with which the Click
device is currently communicating. This only shows the number after
you have autobauded the Click device; when the Click device is not
communicating with a sensor, this option will display a 0.

Server/Client

This setting is not used by the Click 101.

Table 7.4 – Expert Driver Autobaud Tab

The Contact Closures > Sensor tab allows you to change contact closure outputs and the

normal polling routine (see Figure 7.8 and Table 7.5).

Figure 7.8 – Expert Driver Sensor 1 Tab