CHAPTER 7 • CLICK 101
Each side-fire sensor can use its two communication ports to send real-time traffic data to
both cabinets for which it is collecting data (see Figure 7.2). The real-time data is used to
control intersections using distributed and centralized strategies.
Note
The Click 101 data protocol used to poll sensors is supported by SmartSensor HD v1.3
or greater; likewise this protocol is supported in SmartSensor 105 v2.8 or greater.
Traffic
Controller
Figure 7.2 – Each Side-fire SmartSensor Communicates with Two Traffic Controllers
To collect the data at a particular intersection, the Click 101 polls each sensor for real-time
lane-by-lane volume and occupancy data detected since the last polling period. Each poll-
ing period typically takes a few seconds. This data is signalized to the traffic controller or
data logger using up to 16 contact closure outputs.
Figure 7.3 illustrates an example where the Click 101 in Cabinet A can retrieve lane-by-
lane volume and occupancy data from Sensor ID 20 and 21. The data from lanes 4 and 5 of
Sensor ID 20 is used to control phase 2 of the intersection, and the data from lanes 1–3 of
Sensor ID 21 is used to control phase 6. The other lanes from Sensor ID 20 and 21 can be
retrieved by Click 101 devices in cabinets at the adjacent arterial intersections.
- Click 421 (bluetooth to serial converter) (CLK-421) - User Guide Click 342 (lean managed ethernet switch) (CLK-342) - User Guide Click 341 (lean managed ethernet switch) (CLK-341) - User Guide Click 340 (lean managed ethernet switch) (CLK-340) - User Guide Click 331 (unmanaged ethernet switch) (CLK-331) - User Guide Click 330 (unmanaged ethernet switch) (CLK-330) - User Guide Click 304 (RS-232 to RS-485 converter) (CLK-304) - User Guide Click 305 (RS-232 to RS-485 converter) (CLK-305) - User Guide Click 301 (serial to ethernet converter) (CLK-301) - User Guide Click 100 (16 output contact closure) (CLK-100) - User Guide Click 104 (4-channel DIN rail contact closure) (CLK-104) - User Guide Click 110 (4-channel contact closure eurocard) (CLK-110) - User Guide Click 112 (detector rack card) (CLK-112) - User Guide Click 114 (detector rack card) (CLK-114) - User Guide Click 120 (screw terminal relay) (CLK-120) - User Guide Click 121 (spring cage relay) (CLK-121) - User Guide Click 200 (surge suppression) (CLK-200) - User Guide Click 201 (1 amp AC to DC converter) (CLK-201) - User Guide Click 202 (2 amp AC to DC converter) (CLK-202) - User Guide Click 203 (UPS and battery) (CLK-203) - User Guide Click 204 (4 amp AC to DC converter) (CLK-204) - User Guide Click 210 (AC circuit breaker) (CLK-210) - User Guide Click 211 (AC outlet) (CLK-211) - User Guide Click 221 (DC surge protector) (CLK-221) - User Guide Click 222 (system surge protector) (CLK-222) - User Guide Click 223 (dual-485 surge protector) (CLK-223) - User Guide Click 230 (AC surge protector) (CLK-230) - User Guide Click 250 (wireless surge protector) (CLK-250) - User Guide