Accessing the terminal diagnostics menu – Gasboy TopKAT Operation Manual User Manual
Page 87
MDE-4338A TopKAT™ Fuel Management System Operation Manual · February 2009
Page 79
Accessing the Terminal Diagnostics Menu
Diagnostics and Utilities
Accessing the Terminal Diagnostics Menu
When accessing diagnostics functions, pumps must be stopped. If pumps are in run status
(enabled) when entering diagnostic mode, they are returned to run status when diagnostic
mode is exited. Terminal diagnostics are effective only at the master TopKAT when used with
the master/satellite option.
To access the Terminal Diagnostics Menu, proceed as follows:
1
Type DIAG; press ENTER.
• If pumps are not stopped, you are prompted to stop pumps by typing Y for yes or N for no.
• If transactions are in progress, you are queried “Are you sure?. Type Y to enter diagnostics
mode or N to exit.”
The diagnostic Main Menu displays.
MAIN MENU
1. RAM TEST
2. ROM TEST
3. DIP SWITCH TEST
4. HEALTH LIGHT TEST
5. BEEPER TEST
6. DISPLAY TEST
7. KEYPAD TEST
8. DATAKEY TEST
9. PORT TEST
10. DEADMAN TIMER TEST
11. PCMCIA TEST
12. PRINTER TEST
13. QUIT (RESETS SYSTEM)
2
Select the required choice. The test options are covered alphabetically in this section. When
you select the Quit option, the system resets and the SIGN ON: prompt displays.
At the bottom of most test screens, a status line is present which indicates the status of the
current test. Possible values are Idle, Testing, Stopped, Passed, or Failed.
• Idle displays when the submenu for a test is displayed.
• Testing displays while the test is running.
• Stopped displays when a test is stopped using the Start/Stop option.
• Passed or Failed displays as appropriate for the designated test.