MDE-4338A TopKAT™ Fuel Management System Operation Manual · February 2009

Page 57

Config Trans File

Transaction File Setup - Keypad

Record Error Trans

Set Record Error Trans to a YES or NO value.

• YES means that error transactions will be saved in memory.
• NO means that error transactions will not be saved in memory.

Note: Retaining error transactions may be useful in diagnosing system/key problems;

however, if transaction space is at a premium, you may elect not to save error

transactions.

Config Trans Logger

Set Config Trans Logger to an ENABLED or DISABLED value depending on whether you
want to use direct printout mode or not.
Note: If you have a logger (printer) connected to record transactions, be sure to set this value

to ENABLED.

Memory Full Protection

The Memory Full Protection feature is set to YES or NO.

• When set to YES, and transaction memory becomes full, the system will not accept further

transactions and will display a MEMORY FULL message.

• When set to NO, and transaction memory becomes full, the system will start overwriting

transactions, as new transactions occur. This can result in loss of transactions. Refer to

“Move Trans Pointer”

on

page 56

for ways to ease memory-full conditions.