Tank, Pump, and PCU File Setup - Keypad

About the PCU File

Page 52 MDE-4338A TopKAT™ Fuel Management System Operation Manual · February 2009

About the PCU File

The PCU file contains information on the physical setup of your electronic and master/satellite
pumps. The TopKAT can control a total of eight PCUs (or two four-hose mechanical PCUs).

• When you use electronic pumps (9800 or ASTRA), the electronic pump is the PCU (up to

eight electronic hoses can be controlled by a single TopKAT).

• When you use the mechanical I/F, the TopKAT serves as the PCU controlling one or two

mechanical hoses; a master TopKAT can control up to 7 additional satellite TopKATs.

On a 9800 (viewed from the electronic totalizer switch side), the physical left-hand side of the
pump is side 1 or slot 1; the physical right-hand side of the pump is side 2 or slot 2. On a 9820
ASTRA, since there is only one hose, it is always slot 1. The PCU file options allow you to
change slot assignments to vary which side of the pump activates when a pump number is
selected. There can be four slots per PCU for mechanical PCUs.

Because there are six different TopKAT configurations (refer to

“Introduction”

on

page 1

for a

description of each), the PCU setup differs. Use the applicable PCU Assignments section for
your configuration.

Access PCU Setup

To access PCU Setup, proceed as follows:

1

Insert and turn Manager key.

2

Enter password (if required). The COMMAND: SETUP prompt displays. Press ENTER.

3

Press the arrow key until PCU SETUP appears. Press ENTER.

4

Pumps are stopped. If a transaction is in progress, access to the pump file is denied. Pumps are
restarted when the pump file is exited.

PCU Setup/PCU Assignments (Standalone, All Electronic; Master, All
Electronic; Mechanical PCUs)

To enter into the PCU Setup or PCU Assignments, proceed as follows:

1

At PCU SETUP: press ENTER. TopKAT displays Stopping Pumps. At PCU SETUP: PCU
ASSIGNMENTS, press the down arrow.

2

At LOAD # OF PCUs, press ENTER. Load the number of PCUs in your configuration and
press ENTER. Press the down arrow. If your system is standalone, skip to step

4

(step

3

is not

applicable).

3

At LOAD # OF SATELLITES, press ENTER. Load the number of satellites (if applicable)
and press ENTER. Press the down arrow again to return to PCU SETUP: PCU
ASSIGNMENTS.

4

To enter PCU ASSIGNMENTS, press ENTER. The system displays the current slots
assigned to each pump starting with the lowest pump number. For example:

PCU ASSIGNMENTS

PUMP#01 PCU: 1 SLOT: 1

Press the down arrow to display other pumps.