Reports
Print Date/Time
Page 66 MDE-4338A TopKAT™ Fuel Management System Operation Manual · February 2009
Print Date/Time
This report prints the current system date and time.
Print System Configuration (PRINT SYS CONFIG)
This report prints the values loaded for the following system parameters:
• Date
• Program version and program date
• Site number
• System ID
• Number of satellites (master/satellite option only)
• Satellite communication status (master/satellite option only)
• Poll address
• Pump time-out
• Reasonableness range
• Odometer retries
• Invalid PIN lockout
• Manual entry check
• Manual entry name
• Measurement units
• Key receptacle status
• Key read totalizer
• Transaction pointer locations (Oldest=oldest transaction still in memory; Safe=beginning
of the file location; Last=last transaction in memory; Next=next transaction to be
assigned)
Department/Vehicle Report (DEPT/VEHICLE RPT) or
Account Vehicle Report (ACCT/VEHICLE RPT)
This report prints a date range (file initialization date to current) and the following Vehicle file
values in department (or account) order:
• Vehicle number
• Last odometer
• Miles
• Quantity
• MPG
• Department (or account) totals and grand totals for quantity, miles, and average MPG.
Note: When computing grand totals for miles and average MPG, the TopKAT does not
include vehicles that do not enter odometers or whose miles value is zero.