Comtech EF Data CDM-IP 300L User Manual
Page 325

CDM-IP 300L IP-Centric Satellite Modem
Rev. 1
CD/CDMIP300L.IOM
299
10.1.6.4 O
UTDOOR
U
NIT
Fault/Alarm
Possible Problem and Action
CURRENT ODU
Current
fault.
VOLTAGE
ODU Voltage fault.
TEMPERATURE
ODU Temperature fault.
PLL LOCK
PLL Lock fault.
Indicates the PLL is not locked to the reference of the interface transmit
clock recovery oscillator. Contact the Comtech EF Data Customer
Support Department.
CHECKSUM Checksum
fault.
10.1.6.5 C
OMMON
E
QUIPMENT
F
AULTS
Fault/Alarm
Possible Problem and Action
BATTERY/CLOCK M&C
battery voltage or clock fault.
Indicates a low voltage in the memory battery. Typically, this fault will
be active when a modem has been hard reset or the firmware has been
changed. When a hard reset has been executed or the firmware has
been changed, this fault will typically be active when the modem is first
turned on.
-12 VOLT SUPPLY
-12V power supply fault.
Indicates a high or low voltage condition. Level is
± 5%.
Check for a short on the -12V line from the power supply or on any of
the plug-in boards.
+12 VOLT SUPPLY
+12 VDC power supply fault. Use the same procedure as with -12V
fault.
+5 VOLT SUPPLY
+5V power supply fault. Use the same procedure as with a -12V fault.
The +5V supply requires a minimum load of 1A.
CONTROLLER Controller
fault.
Indicates a loss of power in the M&C card. Typically indicates the
controller has gone through a power on/off cycle.
INTERFACE
Interface module fault.
Indicates a problem in programming the interface card.