beautypg.com

Table 45. redundancy oids – Comtech EF Data CDM-IP 300L User Manual

Page 263

background image

CDM-IP 300L IP-Centric Satellite Modem

Rev. 1

CD/CDMIP300L.IOM

237

OID Description

cdmipIgmpMaxRespTime

Defines the time interval (in seconds) that the
modem waits before it assumes that no hosts
are interested in the membership query. The
max response time is 25 seconds.

cdmipIgmpMaxMissBeforeDrop

Number of unanswered queries that must occur
before the modem assumes that group has no
local members and that it need not forward
remotely-originated multicasts for that group
onto the local network.

cdmipIgmpRecognizeQueries

Allows the modem to respond to a Query by
generating Host Membership Reports, telling
each host group to which it belongs on the
network interface from which the Query was
received.

cdmipIgmpVersionUnsolicitedReports Defines which version of the IGMP protocol

should be followed when attempting to join a
host group via an unsolicited report.

cdmipIgmpForceAlertOption

Provides a mechanism whereby routers can
intercept packets not addressed to them directly,
without incurring any significant performance
penalty. Some Cisco routers may require the
definition of a Router Alert Option to recognize a
report from a host to join a host group.

cdmipIgmpUnsolicitedReportInterval

Configures the modem to generate an
unsolicited report within specified time intervals
(in seconds) after joining a host group.

8.5.2.5 R

EDUNDANCY

G

ROUP

Table 45. Redundancy OIDs

OID Description

cdmipCurrentRedundantState

Displays if the modem is Online and
Offline. The Online modem is the one that
will process traffic. The Offline modem
monitors the health of the online unit and
will take over if it detects a failure.

cdmipLocalUnitManagementIpAddress

IP Address for the Ethernet Interface for
the Local Unit.

cdmipRedundantUnitManagementIpAddress IP Address for the Ethernet Interface of

the Remote Unit.

cdmipRedundantTrafficIpAddress

Traffic IP address will always be active on
the Online Modem. When a fault occurs
the traffic IP address will float between
the two redundant modems.