4.2.1.1.4.5 Stored/Faults – Common

DISPLAY SELECTIONS/DESCRIPTION

COMMON 0

11/07/01


Note: “-” indicates status of parameter is OK.

“+” indicates a fault.

Reverse contrast “+” indicates an
alarm.

BATTERY CLOCK

▓------


Battery or clock fault

-12 VOLT SUPPLY

-▓-----


-12 Vdc power supply fault

+12 VOLT SUPPLY

--▓----


+12 Vdc power supply fault

+5 VOLT SUPPLY

---▓---


+5 Vdc power supply fault

SELF TEST

----▓--


Built in self test fault

CONTROLLER

-----▓-


Controller fault. Typically indicates the
controller has gone through a power on/off
cycle

IP MODULE

-------▓


IP module fault. Typically indicates that the IP
module will not program