7 faults/alarms – unaval seconds, 8 faults/alarms – clear, 5 function select - remote aupc (optional) – Comtech EF Data CDM-IP 300L User Manual
Page 106: 1 remote aupc - configuration

CDM-IP 300L IP-Centric Satellite Modem
Rev. 1
CD/CDMIP300L.IOM
80
4.2.1.1.4.7 Faults/Alarms – Unaval Seconds
DISPLAY SELECTIONS/DESCRIPTION
UNAVAL SECONDS 0
NO FAULT
A fault is indicated if the Reed-Solomon
Codec could not correct bit errors in one block
of serialized data in any given second.
Note: This is available only with the Reed-
Solomon option
4.2.1.1.4.8 Faults/Alarms – Clear ??
DISPLAY SELECTIONS/DESCRIPTION
CLEAR ??
STORED FAULTS
CLEAR ??
YES
Select enter to clear all stored faults
4.2.1.1.5 Function
Select
- Remote AUPC (Optional)
DISPLAY SELECTIONS/DESCRIPTION
FUNCTION SELECT
REMOTE AUPC
CONFIGURATION
MONITOR
Note: This is available ONLY with the
ASYNC/AUPC overhead option.
4.2.1.1.5.1 Remote AUPC - Configuration
DISPLAY SELECTIONS/DESCRIPTION
REMOTE AUPC
CONFIGURATION
AUPC ENABLE
ON
ON
OFF
Note: This program is for control of the last
known status.