OID Description
cdmip300LOduCommEnable
Enables or disables communication, via an FSK
serial link, with a Comtech EF Data Transceiver
(Outdoor unit). Can be set to:
0 Disable
1 Enable
8.6.1.6 T
HE
AUPC P
ARAMETERS
Table 59. AUPC Parameter OIDs
OID Description
cdmip300LAupcEnable
Enables or disables AUPC (Automatic Uplink Power
Control). Can be set to:
0 Disable
1 Enable
cdmip300LAupcControlParameters Defines AUPC (Automatic Uplink Power Control)
operating parameters. Has the form abc.cd Where:
a = Define action on max power condition; 0 = do
nothing; 1 = generate TX alarm; b = Define action
on remote demod unlock; 0 = go to nominal power;
1 = go to max power; c = Target E
b
/N
o
value, in dB,
for remote demod; d = Maximum increase in Tx
Power permitted, in dB.
cdmip300LRemoteEbno
Returns the value of Ebi/No of the remote demod, if
Framing is enabled. Returns 999 if demod is
unlocked. Returns -1 if Framing is not enabled.
Ebi/No values can be between 20 and 60 in 0.1
dBs where 20=2.0 dB to 160=16.0 dB.
cdmip300LTxPowerLevelIncrease
Returns the increase in Tx power level, in dB (from
the nominal setting) due to the action of AUPC.
Returns –1 if AUPC is not enabled. Values can be
between 0 and 90 in 0.1 dBm where 0 = 0.0 dBm to
90 = 9.0 dBm