beautypg.com

Stored faults, Tored, Aults – Comtech EF Data CDM-IP 300L User Manual

Page 139

background image

CDM-IP 300L IP-Centric Satellite Modem

Rev. 1

CD/CDMIP300L.IOM

113

Parameter

Type

Protocol

Description

Current
Sweep Value

Command:
Response:

>add/CSV_xsnnnnn'cr''lf]

Where:

x = < or > (data modifier to indicate that the sweep offset value is
less than or greater than the returned value).

s = + or - (sweep offset from center).

nnnnn = 0 to 35000.

yyy = OK or FLT (decoder lock status OK or FAULT).

Notes: 1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.

3. 'Sampling' is returned if not enough data is currently
available to calculate the level.

5.6 S

TORED

F

AULTS

Information on stored faults is returned when requested. If no stored fault exists for a given fault
number, the words “NO Fault” will be returned instead of the normal time/date status
information.

The following symbols are commonly used to define the stored faults status commands:

# Fault number (0 to 9). “0” is the first fault stored.

hh

Hours in 24-hr. format.

mm Minutes.

ss

Seconds.

MM Month.

DD Day.

YYYY Year.

Parameter

Type

Protocol

Description

Modulator
Stored Faults

Command:
Response:

>add/MSF_# hh:mm:ss
MM/DD/YYYYY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SCT_xxx'cr'
EXT_xxx'cr'
CONF_xxx'cr''lf']



Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
Modem Reference PLL Lock (OK/FLT)
Modem Reference Activity (OK/FLT)
Configuration (OK/FLT)

This manual is related to the following products: