Module resolution (-12…30 mv range) – Rockwell Automation 1756-XXXX ControlLogix Analog I/O Modules User Manual
Page 374

374
Publication 1756-UM009C-EN-P - December 2010
Appendix E Additional Specification Information
Module Resolution (-12…30 mV Range)
The table lists the resolution of ControlLogix thermocouple modules when
used in the -12…30 mV input range.
The information represented in the table is shown graphically in the following
illustrations.
Application
Temperature
Module Resolution (in degrees) When Connected to This Thermocouple Type
B
R
S
E
(1)
J
(2)
K
(3)
N
(4)
T
-200 °C (-328 °F)
0.028
0.032
0.046
0.071
0.044
0 °C (32 °F)
0.13
0.13
0.012
0.014
0.018
0.027
0.018
200 °C (392 °F)
0.08
0.08
0.009
0.013
0.018
0.021
0.013
400 °C (752 °F)
0.17
0.07
0.07
0.009
0.013
0.017
0.019
0.011
600 °C (1112 °F)
0.12
0.06
0.07
0.016
0.02
800 °C (1472 °F)
0.09
0.06
0.06
0.02
1000 °C (1832 °F)
0.08
0.05
0.06
1200 °C (2192 °F)
0.07
0.05
0.06
1400 °C (2552 °F)
0.06
0.05
0.06
1600 °C (2919 °F)
0.06
0.05
0.06
1800 °C (3272 °F)
0.06
0.06
0.07
(1)
Type E thermocouples can only be used in applications up to 400 °C (752 °F).
(2)
Type J thermocouples can only be used in applications up to 550 °C (1022 °F).
(3)
Type K thermocouples can only be used in applications up to 700 °C (1292 °F).
(4)
Type N thermocouples can only be used in applications up to 800 °C (1472 °F).
Application Temperature in °C
0.00
0.02
0.04
0.06
0.08
0.10
0.12
0.14
0.16
0.18
0.20
-200
0
200
400
600
800
1000
1200
1400
1600
1800
Minimum Amount of
Degree Change Required
for Thermocouple Module
to Report the Change
Thermocouple Module Resolution - Type B Thermocouple Connection in a -12…30 mV Input Range