4.3 Basic Functions Settings

4-7

4

Op

er

at

io

n

(2) Overtravel Function Setting

Parameters Pn50A and Pn50B can be set to enable or disable the overtravel function.

If the overtravel function is not used, no wiring for overtravel input signals will be required.

A parameter can be used to re-allocate input connector number for the P-OT and N-OT signals. Refer to

3.3.1

Input Signal Allocations

for details.

(3) Servomotor Stopping Method When Overtravel is Used

There are two servomotor stopping methods when an overtravel is used.

• Decelerate to a stop

Stops by using emergency stop torque.

• Coast to a stop

Stops naturally, with no control, by using the friction resistance of the servomotor in operation.

After servomotor stopping, there are two modes.

• Coast mode

Stopped naturally, with no control, by using the friction resistance of the servomotor in operation.

• Zero clamp mode

A mode forms a position loop by using the position reference zero.

The servomotor stopping method when an overtravel (P-OT, N-OT) signal is input while the servomotor is
operating can be set with parameter Pn001.

• A servomotor under torque control cannot be decelerated to a stop. Coast status is maintained after the ser-

vomotor coasts to a stop.

• For details on servomotor stopping methods after the SV_OFF command is received or an alarm occurs,

refer to

4.3.5 Stopping Servomotors after SV_OFF Command or Alarm Occurrence

.

When Servomotor Stopping Method is Set to Decelerate to Stop

Emergency stop torque can be set with Pn406.

• The setting unit is a percentage of the rated torque.
• The factory setting is 800% so that the setting is large enough a value to operate the servomotor at maximum

torque. The maximum value of emergency stop torque that is actually available, however, is limited to the

maximum torque of the servomotor.

Parameter

Meaning

When

Enabled

Classification

Pn50A

n.1

[Factory setting]

Inputs the Forward Run Prohibited (P-OT) signal from
CN1-3.

After restart

Setup

n.8

Disables the Forward Run Prohibited (P-OT) signal.
Allows constant forward rotation.

Pn50B

n.

2

[Factory setting]

Inputs the Reverse Run Prohibited (N-OT) signal from
CN1-8.

n.

8

Disables the Reverse Run Prohibited (N-OT) signal.
Allows constant reverse rotation.

Parameter

Stop Method

Mode After

Stopping

When Enabled Classification

Pn001

n.

02

[Factory setting]

Coast

Coast

After restart

Setup

n.

1

Deceleration to a stop

Zero clamp

n.

2

Coast

Pn406

Emergency Stop Torque

 

 

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Setup

Speed

Position

Torque