beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 289

background image

9.1 List of Parameters

9-7

9

Ap

pend

ix

Pn00C

2

Application Function
Select Switch C

0000 to

0111

0000

After restart

Setup

4.5

Pn00D

2

Application Function
Select Switch D

0000 to

1001

0000

Immediately

Setup

Pn100

2

Speed Loop Gain

10 to 20000

0.1 Hz

400

Immediately

Tuning

5.8.1

Pn101

2

Speed Loop Integral Time
Constant

15 to 51200 0.01 ms

2000

Immediately

Tuning

5.8.1

Pn102

2

Position Loop Gain

10 to 20000

0.1/s

400

Immediately

Tuning

5.8.1

Pn103

2

Moment of Inertia Ratio

0 to 20000

1%

100

Immediately

Tuning

5.8.1

Pn104

2

2nd Speed Loop Gain

10 to 20000 0.1 Hz

400

Immediately

Tuning

5.8.1

Pn105

2

2nd Speed Loop Integral
Time Constant

15 to 51200 0.01 ms

2000

Immediately

Tuning

5.8.1

Pn106

2

2nd Position Loop Gain

10 to 20000

0.1/s

400

Immediately

Tuning

5.8.1

Pn109

2

Feedforward Gain

0 to 100

1%

0

Immediately

Tuning

5.9.1

Pn10A

2

Feedforward Filter Time
Constant

0 to 6400

0.01 ms

0

Immediately

Tuning

5.9.1

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Profile Reference

Section

Selection of Test without a Motor

0

Disables test without a motor.

1

Enables test without a motor.

Encoder Resolution for Test without a Motor

0

13 bits

1

20 bits

Encoder Type for Test without a Motor

0

Incremental encoder

1

Absolute encoder

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Overtravel Warning Detection Selection

Reference

Section

0

Does not detect overtravel warning.

4.3.2

1

Detects overtravel warning.

4th 3rd 2nd 1st

digit digit digit digit

n.