Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual
Page 289
9.1 List of Parameters
9-7
9
Ap
pend
ix
Pn00C
2
Application Function
Select Switch C
0000 to
0111
−
0000
After restart
Setup
−
4.5
Pn00D
2
Application Function
Select Switch D
0000 to
1001
−
0000
Immediately
Setup
−
–
Pn100
2
Speed Loop Gain
10 to 20000
0.1 Hz
400
Immediately
Tuning
−
5.8.1
Pn101
2
Speed Loop Integral Time
Constant
15 to 51200 0.01 ms
2000
Immediately
Tuning
−
5.8.1
Pn102
2
Position Loop Gain
10 to 20000
0.1/s
400
Immediately
Tuning
−
5.8.1
Pn103
2
Moment of Inertia Ratio
0 to 20000
1%
100
Immediately
Tuning
−
5.8.1
Pn104
2
2nd Speed Loop Gain
10 to 20000 0.1 Hz
400
Immediately
Tuning
−
5.8.1
Pn105
2
2nd Speed Loop Integral
Time Constant
15 to 51200 0.01 ms
2000
Immediately
Tuning
−
5.8.1
Pn106
2
2nd Position Loop Gain
10 to 20000
0.1/s
400
Immediately
Tuning
−
5.8.1
Pn109
2
Feedforward Gain
0 to 100
1%
0
Immediately
Tuning
−
5.9.1
Pn10A
2
Feedforward Filter Time
Constant
0 to 6400
0.01 ms
0
Immediately
Tuning
−
5.9.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
Selection of Test without a Motor
0
Disables test without a motor.
1
Enables test without a motor.
Encoder Resolution for Test without a Motor
0
13 bits
1
20 bits
Encoder Type for Test without a Motor
0
Incremental encoder
1
Absolute encoder
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
Reference
Section
0
Does not detect overtravel warning.
4.3.2
1
Detects overtravel warning.
4th 3rd 2nd 1st
digit digit digit digit
n.