beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 318

background image

9 Appendix

9.1.3 MECHATROLINK-

III

Common Parameters

9-36

81

PnB02

4

Exponential Function Accel/Decel
Time Constant

0 to 510000

μ

s

[0.1 ms]

0

Immedi-

ately

*5

Command

Related

Parameters

82

PnB04

4

Movement Average Time

0 to 510000

μ

s

[0.1 ms]

0

Immedi-

ately

*5

83

PnB06

4

Final Travel Distance for External
Positioning

–1073741823

to 1073741823

1 reference unit

100

Immedi-

ately

84

PnB08

4

Homing Approach Speed

0 to

3FFFFFFFH

10

-3

min

-1

500

Value

converted

reference/s

into 10

-3

min

-1

Immedi-

ately

85

PnB0A

4

Homing Creep Speed

0 to

3FFFFFFFH

10

-3

min

-1

500

Value

converted

reference/s

into 10

-3

min

-1

Immedi-

ately

86

PnB0C

4

Final Travel Distance for Homing

–1073741823

to 1073741823

1 reference unit

100

Immedi-

ately

87

PnB0E

4

Monitor Selection 1

0 to F

1

Immedi-

ately

0000H

APOS

0001H

CPOS

0002H

PERR

0003H

LPOS1

0004H

LPOS2

0005H

FSPD

0006H

CSPD

0007H

TRQ

0008H

ALARM

0009H

MPOS

000AH

Reserved (Undefined value)

000BH

Reserved (Undefined value)

000CH

CMN1 (Common monitor 1)

000DH

CMN2 (Common monitor 2)

000EH

OMN1 (Optional monitor 1)

000FH

OMN2 (Optional monitor 2)

88

PnB10

4

Monitor Selection 2

0

Immedi-

ately

0000H
to
000FH

Same as Monitor Selection 1.

∗5.

Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
operation.

Parameter

No.

Size

Name

Setting Range

Units

[Resolution]

Factory

Setting

When

Enabled

Classifica-

tion