beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 292

background image

9 Appendix

9.1.2 Parameters

9-10

Pn143

2

Model Following Control
Bias
(Forward Direction)

0 to 10000

0.1%

1000

Immediately

Tuning

Pn144

2

Model Following Control
Bias

(Reverse Direction)

0 to 10000

0.1%

1000

Immediately

Tuning

Pn145

2

Vibration Suppression 1
Frequency A

10 to 2500

0.1 Hz

500

Immediately

Tuning

Pn146

2

Vibration Suppression 1
Frequency B

10 to 2500

0.1 Hz

700

Immediately

Tuning

Pn147

2

Model Following Control

Speed Feedforward Com-
pensation

0 to 10000

0.1%

1000

Immediately

Tuning

Pn148

2

2nd Model Following
Control Gain

10 to 20000

0.1/s

500

Immediately

Tuning

Pn149

2

2nd Model Following
Control Gain Compensa-
tion

500 to 2000

0.1%

1000

Immediately

Tuning

Pn14A

2

Vibration Suppression 2
Frequency

10 to 2000

0.1 Hz

800

Immediately

Tuning

Pn14B

2

Vibration Suppression 2
Compensation

10 to 1000

1%

100

Immediately

Tuning

Pn14F

2

Control Related Switch

0000 to

0011

0011

After restart

Tuning

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Profile Reference

Section

Model Following Control Type Selection

Reference

Section

0

Model Following Control 1

5.3.1,
5.4.1,

5.5.1

1

Model Following Control 2

Tuning-less Type Selection

Reference

Section

0

Tuning-less type 1

5.2.2

1

Tuning-less type 2

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit