Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual
Page 316
9 Appendix
9.1.3 MECHATROLINK-
III
Common Parameters
9-34
26
PnA4C
4
Forward Software Limit
–1073741823
to
1073741823
1 reference unit
1073741823
Immedi-
ately
Machine
Specification
Related
Parameters
27
PnA4E
4
Reserved (Do not use.)
–
–
0
Immedi-
ately
28
PnA50
4
Reverse Software Limit
–1073741823
to
1073741823
1 reference unit
–1073741823
Immedi-
ately
29
PnA52
4
Reserved (Do not use.)
–
–
0
Immedi-
ately
41
PnA82
4
Speed Unit
0 to 4
–
0
After
restart
Unit System
Related
Parameters
0000H
reference unit/sec
0001H
reference unit/min
0002H
Percentage (%) of rated speed
*2
0003H
min
-1*2
0004H
Max. motor speed/40000000H
*3
42
PnA84
4
Speed Base Unit
(Set the value of “n” used as the
exponent in 10
n
when calculating
the Speed Unit (41).)
*2*3
–3 to 3
–
0
After
restart
43
PnA86
4
Position Unit
0
–
0
After
restart
0000H
reference unit
44
PnA88
4
Position Base Unit
(Set the value of “n” used as the
exponent in 10
n
when calculating
the Position Unit (43).)
0
–
0
After
restart
45
PnA8A
4
Acceleration Unit
–
–
0
After
restart
0000H
reference unit/sec
2
0001H
Not supported
46
PnA8C
4
Acceleration Base Unit
(Set the value of “n” used as the
exponent in 10
n
when calculating
the Acceleration Unit (45).)
4 to 6
–
4
After
restart
47
PnA8E
4
Torque Unit
1 to 2
–
1
After
restart
0000H
Not supported
0001H
Percentage (%) of rated torque
0002H
Max. torque/40000000H
*4
48
PnA90
4
Torque Base Unit
*4
(Set the value of “n” used as the
exponent in 10
n
when calculating
the Torque Unit (47).)
–5 to 0
–
0
After
restart
∗2.
When 0003H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to a number
between -3 and 0.
∗3.
When 0004H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to 0.
∗4.
When 0002H is selected for the Torque Unit (parameter 47), set the Torque Base Unit (parameter 48) to 0.
Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or
the power must be turned OFF and then ON again.
Parameter
No.
Size
Name
Setting Range
Units
[Resolution]
Factory
Setting
When
Enabled
Classifica-
tion