6 Utility Functions (Fn

)

6-16

6.6

Initializing Parameter Settings (Fn005)

This function is used when returning to the factory settings after changing parameter settings.

Note: Any value adjusted with Fn00C, Fn00D, Fn00E, and Fn00F cannot be initialized by Fn005.

(1) Preparation

The following conditions must be met to initialize the parameter values.

• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.

(2) Operating Procedure

Use the following procedure.

1.

In the SigmaWin+ main window, click

Parameters

-

Edit Parameters

.

The

Parameter Editing

dialog box will appear.

• Be sure to initialize the parameter settings while the servomotor power is OFF

.

• After initialization, restart the SERVOPACK to validate the settings.