beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 309

background image

9.1 List of Parameters

9-27

9

Ap

pend

ix

Pn82C

2

Option Field Allocation 3

0000 to

1F1F

1F1E

After restart

Setup

M2

*6

Pn82D

2

Option Field Allocation 4

0000 to

1F1C

0000

After restart

Setup

M2

*6

Pn82E

2

Option Field Allocation 5

0000 to

1D1F

0000

After restart

Setup

M2

*6

∗6.

This parameter is enabled only for MECHATROLINK-II-compatible profile.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Profile Reference

Section

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

0 to F

P_CL bit position

0

1

Disables P_CL bit allocation.

Enables P_CL bit allocation.

0 to F

N_CL bit position

0

1

Disables N_CL bit allocation.

Enables N_CL bit allocation.

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

0 to C

BANK_SEL1 bit position

0

1

Disables BANK_SEL1 bit allocation.

Enables BANK_SEL1 bit allocation.

0 to F

LT_DISABLE bit position

0

1

Disables LT_DISABLE bit allocation.

Enables LT_DISABLE bit allocation.

4th 3rd 2nd 1st

digit digit digit digit

n.

Reserved (Do not change.)

Reserved (Do not change.)

0 to D

OUT_SIGNAL bit position

0

Disables OUT_SIGNAL bit allocation.

1

Enables OUT_SIGNAL bit allocation.