M-iii – Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual
Page 286

9 Appendix
9.1.2 Parameters
9-4
Pn002
2
Application Function
Select Switch 2
0000 to
4113
−
0011
After restart
Setup
−
−
Pn006
2
Application Function
Select Switch 6
0000 to
005F
−
0002
Immediately
Setup
−
5.1.3
∗1.
For details, refer to
Σ
-V Series User’s Manual MECHATROLINK-III Standard Servo Profile Commands
(Manual
No.: SIEP S800000 63).
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
4th 3rd 2nd 1st
digit digit digit digit
n.
M-III
MECHATROLINK Command Position and Speed Control Option
Reference
Section
0
Reserved (Do not change.)
*1
1
TLM operates as the torque limit value.
2
Reserved (Do not change.)
3
Reserved (Do not change.)
Torque Control Option
Reference
Section
0
Reserved (Do not change.)
–
1
V_LIM operates as the speed limit value.
–
Absolute Encoder Usage
Reference
Section
0
Uses absolute encoder as an absolute encoder.
4.7
1
Uses absolute encoder as an incremental encoder.
Reserved (Do not change.)
Analog Monitor 1 Signal Selection
00
Motor rotating speed (1 V / 1000 min
-1
)
01
Speed reference (1 V / 1000 min
-1
)
02
Torque reference (1 V/100% rated torque)
03
Position error (0.05 V/1 reference unit)
04
Position amplifier error (after electronic gears) (0.05 V/ 1 encoder pulse unit)
05
Position reference speed (1 V / 1000 min
-1
)
06
Reserved (Do not change.)
07
Reserved (Do not change.)
08
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
09
Reserved (Do not change.)
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
Completion of position reference (completed: 5 V, not completed: 0 V)
0D
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.