6.8 Offset Adjustment of Analog Monitor Output (Fn00C)

6-21

6

Utili

ty Fu

ncti

ons (Fn

)

(3) Operating Procedure

Use the following procedure.

1.

Connect the measurement instrument.

For details, refer to

5.1.3

(1) Connecting the Measurement Instrument

.

2.

In the SigmaWin+ main window, click

Setup

-

Adjust Offset

-

Adjust the Analog Monitor

Output

. The

Adjust the Analog Monitor Output

box will appear. Click

Zero Adjustment

tab.

In the

Channel

box, either CH1 or CH2 can be selected.

3.

To adjust the offset, click

+1

(increase) or

-1

(decrease) button while viewing the analog monitor

to check the output level. Keep the output as close to zero as possible.