beautypg.com

2 troubleshooting of alarms – Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 260

background image

8.1 Alarm Displays

8-5

8

Trou

blesh

ooting

8.1.2

Troubleshooting of Alarms

If an error occurs in the servo drive, the ALM signal will be output. The alarm that occurs can be checked on

the

Alarm Display

dialog box of the SigmaWin+.

Refer to the following table to identify the cause of an alarm and the action to be taken.

Contact your Yaskawa representative if the problem cannot be solved by the described corrective action.

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

A.020:
Parameter Checksum

Error 1

(The parameter data in
the SERVOPACK is
incorrect.)

The power supply voltage sud-
denly dropped.

Measure the power supply voltage.

Set the power supply voltage within
the specified range, and set Fn005

to initialize the parameter.

The power supply went OFF

while changing a parameter set-
ting.

Check the circumstances when the
power supply went OFF.

Set Fn005 to initialize the parameter
and then set the parameter again.

The number of times that parame-
ters were written exceeded the

limit.

Check to see if the parameters were
frequently changed through the host

controller.

The SERVOPACK may be faulty.
Replace the SERVOPACK.
Reconsider the method of writing
parameters.

Malfunction caused by noise
from the AC power supply or
grounding line, static electricity
noise, etc.

Restart the SERVOPACK several
times. If the alarm still occurs, there
may be noise interference.

Take countermeasures against
noise.

Gas, water drops, or cutting oil
entered the SERVOPACK and
caused failure of the internal
components.

Check the installation conditions.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A SERVOPACK fault occurred.

Restart the SERVOPACK several
times. If the alarm still occurs, the
SERVOPACK may be faulty.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.021:
Parameter Format

Error 1

(The parameter data in
the SERVOPACK is
incorrect.)

The software version of SERVO-
PACK that caused the alarm is
older than that of the written
parameter.

Check Fn012 to see if the set soft-
ware version agrees with that of the
SERVOPACK. If not, an alarm may
occur.

Write the parameter of another
SERVOPACK of the same model
with the same software version.
Restart the SERVOPACK.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.022:
System Checksum

Error 1

(The parameter data in
the SERVOPACK is

incorrect.)

The power supply voltage sud-
denly dropped.

Measure the power supply voltage.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

The power supply went OFF
while setting a utility function.

Check the circumstances when the
power supply went OFF.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A SERVOPACK fault occurred.

Restart the SERVOPACK several
times. If the alarm still occurs, the
SERVOPACK may be faulty.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.030:
Main Circuit Detector

Error

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.040:
Parameter Setting

Error 1

(The parameter setting
was out of the setting
range.)

The SERVOPACK and servomo-
tor capacities do not match each
other.

Check the combination of SERVO-
PACK and servomotor capacities.

Select the proper combination of
SERVOPACK and servomotor
capacities.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

The parameter setting is out of
the setting range.

Check the setting ranges of the
parameters that have been changed.

Set the parameter to a value within
the setting range.

The electronic gear ratio is out of
the setting range.

Check the electronic gear ratio. The
ratio must satisfy:
0.001< (Pn20E/Pn210) < 4000.

Set the electronic gear ratio in the
range: 0.001< (Pn20E/Pn210)
< 4000.