beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 149

background image

5.4 Advanced Autotuning by Reference (Fn202)

5-39

5

Adjustments

9.

Turn the servo on and then input the reference from the host controller. Click

Start tuning

.

10.

After confirming the safety of the area adjoining the drive unit, click

Yes

.

The motor will start rotating and tuning will start.

Vibration generated during tuning is automatically detected, and the optimum setting for the detected
vibration will be made. When the setting is complete, the LED indicator lamps (bottom left of the box) of

the functions used for the setting will light up.

11.

When tuning is completed, click

Finish

to return to the main window.

The results of tuning will be written in the parameters.

MECHA