5.5 One-parameter Tuning (Fn203)

5-49

5

Adjustments

Functions To Suppress Vibration

For vibration frequencies above 1,000 Hz when servo gains are increased, the notch filter auto setting function
provides effective suppression. For vibration frequencies between 100 and 1,000 Hz, the anti-resonance con-

trol adjustment auto setting function is effective.

• Auto Setting

To use auto setting, enable the notch filter/anti-resonance control adjustment auto setting function by using

parameters.
During tuning, the notch filter frequency (anti-resonance control frequency for the anti-resonance control

adjustment auto setting function) effective for the detected vibration is automatically set and displayed in

1

step

or

2 step

(in

Anti-res Adj

when using the anti-resonance control adjustment auto setting function).

Window with Notch Filter Automatically Set

• Cancel

If the automatically set notch filter frequency (or anti-resonance control frequency) does not effectively

suppress vibration, click

Cancel

to reset to the preceding frequency.

When the frequency is reset, vibration detection will restart.

• Vib Detect (vibration detection)

While the notch filter/anti-resonance control adjustment auto setting function is enabled, click

Vib

Detect

(vibration detection) to manually detect vibration. The SERVOPACK detects vibration at the

moment

Vib Detect

(vibration detection) is clicked, and the notch filter frequency (or anti-resonance

control frequency) effective for the detected vibration is set and displayed in

1 step

or

2 step

(or in

Anti-res Adj

). Manual vibration detection can also be executed when the SERVOPACK does not detect

vibration.

• Anti-res Ctrl Adj (anti-resonance control)

Click

Anti-res Ctrl Adj

(anti-resonance control) to execute the anti-resonance control function if fur-

ther adjustment is required. See

5.6 Anti-Resonance Control Adjustment Function (Fn204)

for details.

To Autotuning

Click

To Autotuning

to execute autotuning using reference inputs from the host controller. Refer to

5.4

Advanced Autotuning by Reference (Fn202)

for details.

MECHA