Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual
Page 330

9 Appendix
9-48
Pn901
0
Parameter Bank Member Number
After restart
Pn902 to
Pn910
0
Parameter Bank Member Definition
After restart
Pn920 to
Pn95F
0
Parameter Bank Data (nonvolatile
memory save disabled)
Immediately
01
PnA02
–
Encoder Type (read only)
–
02
PnA04
–
Motor Type (read only)
–
03
PnA06
–
Reserved (Do not use.)
–
04
PnA08
–
Rated Speed (read only)
–
05
PnA0A
–
Maximum Output Speed (read only)
–
06
PnA0C
–
Speed Multiplier (read only)
–
07
PnA0E
–
Rated Torque (read only)
–
08
PnA10
–
Maximum Output Torque (read only)
–
09
PnA12
–
Torque Multiplier (read only)
–
0A
PnA14
–
Resolution (read only)
–
21
PnA42
1
Electronic Gear Ratio (Numerator)
After restart
22
PnA44
1
Electronic Gear Ratio (Denominator)
After restart
23
PnA46
0
Absolute Encoder Origin Offset
Immediately
∗
1
24
PnA48
65535
Multiturn Limit Setting
After restart
25
PnA4A
0000H
Limit Setting
After restart
26
PnA4C
1073741823
Forward Software Limit
Immediately
27
PnA4E
0
Reserved (Do not use.)
Immediately
28
PnA50
-1073741823
Reverse Software Limit
Immediately
29
PnA52
0
Reserved (Do not use.)
Immediately
41
PnA82
0
Speed Unit
After restart
42
PnA84
0
Speed Base Unit
After restart
43
PnA86
0
Position Unit
After restart
∗1.
Enabled after the SENS_ON command is input.
Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or
the power must be turned OFF and then ON again.
(cont’d)
Parameter
Factory
Setting
Name
When
Enabled