9 Appendix

9.1.2 Parameters

9-28

Pn833

2

Motion Setting

0000 to

0001

0000

After restart

Setup

*1

Pn834

4

1st Linear Acceleration
Constant 2

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*4

Setup

*1

Pn836

4

2nd Linear Acceleration

Constant 2

1

to

20971520

10000

reference

unit/s

100

Immediately

*4

Setup

*1

Pn838

4

Acceleration Constant
Switching Speed 2

0 to

2097152000

1

reference

unit/s

0

Immediately

*4

Setup

*1

Pn83A

4

1st Linear Deceleration
Constant 2

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*4

Setup

*1

Pn83C

4

2nd Linear Deceleration
Constant 2

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*4

Setup

*1

Pn83E

4

Deceleration Constant
Switching Speed 2

0

to

2097152000

1

reference

unit/s

0

Immediately

*4

Setup

*1

Pn840

4

Linear Deceleration
Constant 2 for Stopping

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*4

Setup

*1

Pn842

*7

4

Homing Approach Speed
(Homing Approach Speed
12)

0 to

20971520

100

reference

unit/s

0

Immediately

*4

Setup

*1

Pn850

2

Latch Sequence Number

0

to

8

0

Immediately

Setup

*1

Pn851

2

Continuous Latch Count

0

to

255

0

Immediately

Setup

*1

∗1.

For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-III Standard Servo Profile Commands

(Manual

No.: SIEP S800000 63).

∗4.

Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
operation.

∗7.

The set value of Pn842 is valid when the set value of Pn817 is 0. Software version 0023 or higher is required to use

Pn842.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Profile Reference

Section

4th 3rd 2nd 1st

digit digit digit digit

n.

Linear Accel/Decel Constant Selection

0

Uses Pn80A to Pn80F and Pn827. (Setting of Pn834 to Pn840 disabled)

1

Uses Pn834 to Pn840. (Setting of Pn80A to Pn80F and Pn827 disabled)

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)