8 Troubleshooting

8.1.2 Troubleshooting of Alarms

8-12

A.C92:
Encoder

Communications

Timer Error

Noise interference occurred on
the I/O signal line from the
encoder.

Take countermeasures against noise
for the encoder wiring.

Excessive vibration and shocks
were applied to the encoder.

Check the operating environment.

Reduce the machine vibration or
correctly install the servomotor.

An encoder fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the servomotor
may be faulty. Replace the servo-

motor.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.CA0:
Encoder Parameter

Error

An encoder fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the servomotor

may be faulty. Replace the servo-
motor.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.Cb0:
Encoder Echoback

Error

The wiring and contact for
encoder cable are incorrect.

Check the wiring.

Correct the wiring.

Noise interference occurred due
to incorrect cable specifications
of encoder cable.

Use tinned annealed copper
shielded twisted-pair or screened
unshielded twisted-pair cable with a
core of at least 0.12 mm

2

.

Noise interference occurred
because the wiring distance for
the encoder cable is too long.

The wiring distance must be 50 m
max.

The FG potential varies because
of influence from machines on

the servomotor side, such as the
welder.

Check the cable layout for encoder

cable.

Properly ground the machines to

separate from encoder FG.

Excessive vibration and shocks
were applied to the encoder.

Check the operating environment.

Reduce the machine vibration or
correctly install the servomotor.

An encoder fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the servomotor
may be faulty. Replace the servo-
motor.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.CC0:
Multiturn Limit

Disagreement

The multiturn limit value of the
encoder is different from that of
the SERVOPACK. Or, the multi-
turn limit value of the SERVO-
PACK has been changed.

Check the value of the Pn205 of the
SERVOPACK.

Execute Fn013 at the occurrence of
alarm.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions