beautypg.com

3 basic functions settings, 1 servomotor rotation direction – Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 70

background image

4.3 Basic Functions Settings

4-5

4

Op

er

at

io

n

4.3

Basic Functions Settings

This section describes how to set the basic functions for operation.

4.3.1

Servomotor Rotation Direction

The servomotor rotation direction can be reversed with parameter Pn000.0 without changing the polarity of

the speed/position reference.

The standard setting for forward rotation is counterclockwise (CCW) as viewed from the load end of the ser-

vomotor.

Note: SigmaWin+ trace waveforms are shown in the above table.

Parameter

Forward/

Reverse

Reference

Direction of Motor Rotation

Applicable

Overtravel (OT)

Pn000

n.

0

Sets CCW as

forward direction.
[Factory setting]

Forward
Reference

P-OT

Reverse
Reference

N-OT

n.

1

Sets CW as

forward direction.

(Reverse Rotation

Mode)

Forward
Reference

P-OT

Reverse
Reference

N-OT

CCW

Time

Motor speed

Torque reference

Motor speed

+

CW

Time

Motor speed

Torque reference

Motor speed

+

CW

Motor speed

Torque reference

Motor speed

+

Time

CCW

+

Time

Motor speed

Torque reference

Motor speed