5.3 Advanced Autotuning (Fn201)

5-29

5

Adjustments

21.

After confirming the safety of the area adjoining the drive unit, click

Yes

.

The motor will start rotating and tuning will start.

Vibration generated during tuning is automatically detected, and the optimum setting for the detected

vibration will be made. When the setting is complete, the LED indicator lamps (bottom left of the box) of
the functions used for the setting will light up.

22.

When tuning is completed, click

Finish

to return to the main window.

The results of tuning will be written in the parameters.

MECHA