3.3 I/O Signal Allocations

3-11

3

Wirin

g and

Co

nnectio

n

Example of Changing Input Signal Allocations

The procedure to set the forward run prohibited signal (P-OT) allocated CN1-3 to “enable forward drive” and

instead allocate the forward external torque limit signal (P-CL) to CN1-3 is shown below.

• Pn50A is changed from n.1881 to n.8881.
• Pn50B is changed from n.8882 to n.8182.