3 related parameters – Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual
Page 127
5.2 Tuning-less Function
5-17
5
Adjustments
5.2.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Name
Mid-execution
changes
Automatic
changes
Pn170
Tuning-less Function Related Switch
No
Yes
Pn401
Torque Reference Filter Time Constant
No
Yes
Pn40C
2nd Notch Filter Frequency
No
Yes
Pn40D
2nd Notch Filter Q Value
No