2 parameters, Mecha – Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual
Page 285

9.1 List of Parameters
9-3
9
Ap
pend
ix
9.1.2
Parameters
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
Pn000
2
Basic Function Select
Switch 0
0000 to
00B3
−
0000
After restart
Setup
−
−
Pn001
2
Application Function
Select Switch 1
0000 to
1122
−
0000
After restart
Setup
−
−
4th 3rd 2nd 1st
digit digit digit digit
n.
MECHA
Direction Selection
Reference
Section
0
Sets CCW as forward direction.
4.3.1
1
Sets CW as forward direction. (Reverse Rotation Mode)
2 to 3
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Overtravel (OT) Stop Mode
Reference
Section
0
Stops the motor by coasting.
4.3.2
1
Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to servolock state.
2
Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to coasting state.
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.