9.1 List of Parameters

9-3

9

Ap

pend

ix

9.1.2

Parameters

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Profile Reference

Section

Pn000

2

Basic Function Select
Switch 0

0000 to

00B3

0000

After restart

Setup

Pn001

2

Application Function
Select Switch 1

0000 to

1122

0000

After restart

Setup

4th 3rd 2nd 1st

digit digit digit digit

n.

MECHA

Direction Selection

Reference

Section

0

Sets CCW as forward direction.

4.3.1

1

Sets CW as forward direction. (Reverse Rotation Mode)

2 to 3

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Overtravel (OT) Stop Mode

Reference

Section

0

Stops the motor by coasting.

4.3.2

1

Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to servolock state.

2

Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to coasting state.

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.