Setting up the Level 10R Gig E switch

opens.

25.If you need a trunk for ISLs to gang switches together, use the following steps.

These steps illustrate trunking the last three 1 Gig ports for three 1 Gig ISLs, which
is the recommended configuration for ISLs on all multi-switch K2 Storage
Systems. Refer to

“Design considerations for Ethernet switches” on page 559

and

consult with your Grass Valley representative if your requirements deviate from
the recommended policy:

a. At the main menu, select

Switch Configuration

and press

Enter

.

b. Choose selection

Port/Trunk Settings

and press

Enter

.

c. Press the right-arrow key to choose

Edit

, then press

Enter

.

d. Down arrow until at the bottom of the list of ports and select the last (highest

port number) 1 Gig port in the list.

e. Right-arrow over to the Group column.

f. Use the Space bar and set the bottom 1 Gig port to

Trk1

.

g. Set the next port up also to

Trk1

.

h. Set the next port up also to

Trk1

.

i. Press

Enter

, then right-arrow to

Save

. Press

Enter

and revert to previous menu.

26.Select

Return to Main Menu

and press

Enter

.

27.From the main menu, tab to

Command Line (CLI)

and press

Enter

. The command

prompt appears.

28.Check the version of firmware currently installed on the switch. Type the

following, then press

Enter

:

show flash

Information is displayed similar to the following example:

HP_iSCSI_switch1# show flash

Image Size(Bytes) Date Version

----- ---------- -------- -------

Primary Image : 6737518 07/25/08 T.13.23

Secondary Image : 5886358 10/26/06 T.11.12

Boot Rom Version: K.12.12

Current Boot : Primary

29.Check the Primary Image Version and refer to your K2 Release Notes for

information about currently supported versions. Then proceed as follows:

• If K2 Release Notes instruct you to change the firmware on the switch, do so

before continuing. Refer to the documentation you received with the switch for
instructions to change the firmware. Then continue with the next procedure.

• If K2 Release Notes confirm that the version on the switch is a currently

supported version, continue with the next procedure.