K2 Storage System Instruction Manual
June 25, 2009
Chapter 8 Installing the Nearline 10 Storage System
you type the following, then press
Enter
.
telnet 192.168.40.12
b. Press
Enter
one or more times until the switch’s username prompt appears.
c. Type the switch’s administrator username and press
Enter
, then type the
switch’s administrator password and press
Enter
. The switch console command
(CLI) prompt appears.
2. Type the following, then press
Enter
:
config
You are now in configuration mode.
3. Type the following, then press
Enter
:
show qos vlan
The screen displays VLAN information. Note the ID number of the Media (iSCSI)
VLAN. It should be 60, as follows:
VLAN priorities
VLAN ID Apply rule | DSCP Priority
------- ----------- + ------ -----------
1 No-override | No-override
60 No-override | No-override
a. Assign the Media VLAN the QOS priority of 3. For example, if the VLAN ID
is 60, you type the following, then press
Enter
.
vlan 60 qos priority 3
4. Type the following, then press
Enter
:
show qos vlan
The screen displays VLAN information. Make sure that the Priority column reports
that the Media VLAN has a value of 3.
Verifying the flow control setting on the GigE switch
Prerequisites for this procedure are as follows:
• The switch is HP ProCurve switch 2900 series.
• Trunks, VLANs, QOS, and all other configuration is complete.
• The switch has an IP address
• You have network access to the switch
Use this procedure to check flow control settings, and if necessary, configure flow
control to “off” (disabled) for all ports.
1. If you have not already done so, from a network connected PC open the MS-DOS
command prompt and login to the switch as administrator, as follows: