Configuring Level 3, 10, 20, 30 RAID chassis network and SNMP settings
For the Level 2 RAID chassis, network and SNMP settings are set and stored on the
LAN card. Therefore, if the RAID chassis has two RAID controllers, they are
configured as a single device, as in the following procedure.
1. In the Storage Utility, right-click the icon for a RAID controller and select
Configuration | Network Properties
. The Network Settings dialog box opens.
2. Enter network settings.
3. For each SNMP manager to which you want to send SNMP trap messages, enter
the IP address of the PC hosting the manager. For monitoring with NetCentral,
enter the IP address of the NetCentral server PC.
4. Click
OK
to save settings and close.
5. Restart the RAID chassis to put SNMP configuration changes into effect.
Configuring Level 3, 10, 20, 30 RAID chassis network and SNMP
settings
Through Storage Utility you can configure the following settings on a RAID chassis:
• IP address
• Subnet mask
• Gateway Address