Setting up the nh1-10ge k2 media server – Grass Valley K2 Storage System Instruction Manual v.3.3 User Manual
Page 203
June 25, 2009
K2 Storage System Instruction Manual
203
Setting up the NH1-10GE K2 Media Server
Setting up the NH1-10GE K2 Media Server
If your system has one or more NH1-10GE K2 Media Servers, prepare the servers
using this section.
The Dell PowerEdge 1950 is qualified as the platform for the NH1-10GE K2 Media
Server.
Do the following to prepare a NH1-10GE K2 Media Server:
• Install the server in its permanent location. Refer to the rack mount instructions that
you received with the server’s product bundle.
• Provide power to the server.
• Connect cables as follows:
Connect the motherboard GigE port 1 (control) to a control port on the GigE
switch. If you have more than one NH1-10GE server, balance servers between
the A GigE switch and the B GigE switch.
Connect the 10 Gig FTP port to the 10 Gig port on the rear of the GigE switch.
If you have more than one NH1-10GE server, balance servers between the A
GigE switch and the B GigE switch.
Connect the Fibre Channel port to the RAID storage device. If you have more
than one NH1-10GE server, balance servers between controller 0 and controller
1.
• Assign a control network IP address to GigE port 1. Use standard Windows
procedures. Refer to
“Networking tips” on page 112
.
• Change the hostname. Use standard Windows procedures.
• Configure SNMP properties so the trap destination points to the NetCentral server
PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.
“K2 Media Server descriptions” on page 413
.
1
2
Gb 2
Gb 1
FTP: To 10 Gig port
on GigE switch
Fibre Channel
to RAID controller
To control port
on GigE switch