Configuring RAID
Utility opens.
3. In Storage Utility tree view, expand the node for the Nearline 10 RAID, right-click
the icon for a Nearline 10 RAID controller, and select
Configuration | Network
Properties
.
The Controller Network Settings dialog box opens.
For a Nearline 10 RAID chassis with two controllers, you can make settings on
both controllers using this dialog box.
4. In the Controller Slot Number field enter
0
and then press
Enter
. The settings from
controller 0 are loaded into the Controller Network Settings dialog box and are
available for you to modify.
5. Enter the control network IP address and other network settings.
6. You want SNMP trap messages go to the NetCentral server PC, so for SNMP
Configuration enter the IP address of the NetCentral server PC. You can also enter
IP addresses for other SNMP managers to which you want to send SNMP trap
messages.
7. For the RAID chassis with two controllers, in the Controller Slot Number field
enter
1
and then press
Enter
. The settings from controller 1 are loaded into the
Controller Network Settings dialog box and are available for you to modify. Repeat
the previous steps to configure controller 1.
8. Click
OK
to save settings and close.