Cabling the switch

Cabling the switch

• Install the switch in its permanent location.

• Provide power to the switch.

• Use CAT5e or CAT6 cables. The maximum cable length is 50 meters for CAT5e

and 100 meters for CAT6.

• Connect cables as follows:

2900 series switch

To the media ports make one iSCSI connection from each K2 Media Client or other
iSCSI client, and one iSCSI connection from the K2 Media Server.

To the control ports make a connection from each K2 Media Client or other iSCSI
client, from the RAID storage chassis, and from the control point PC. Also make
the FTP network connection and the control network connection from the K2
Media Server.

Refer to cabling procedures later in this chapter for the GigE connections at each of
the devices of the K2 Storage System.

Setting up the Level 10 K2 Media Server

The Dell PowerEdge 1950 is qualified as the platform for the GS K2 Media Server.

Do the following to prepare the GS K2 Media Server:

• Install the server in its permanent location. Refer to the rack mount instructions that

you received with the server’s product bundle.

• Provide power to the servers.

• Connect cables as follows:

Dell 1950 PowerEdge server

Control ports

Media (iSCSI) ports

1

2

Gb 2

Gb 1

To media (iSCSI)
port on GigE switch

Fibre Channel
to RAID controller

To control port
on GigE switch

FTP: To control port
on GigE switch