Configuring raid, Configuring raid network and snmp settings – Grass Valley K2 Storage System Instruction Manual v.3.3 User Manual
Page 392
392
K2 Storage System Instruction Manual
June 25, 2009
Chapter 8 Installing the Nearline 10 Storage System
3. Continue with the next procedure to use Storage Utility to configure the file
system.
Leave the Configure K2 Server wizard open while you are using Storage Utility.
When you are done with Storage Utility, you continue with the wizard.
Configuring RAID
Use Storage Utility to complete the configuration of the Nearline 10 RAID chassis, as
explained in the following topics:
Configuring RAID network and SNMP settings
Use the Storage Utility to configure the following settings for the Nearline RAID
controller or controllers:
• IP address
• Subnet mask
• Gateway Address
• SNMP trap destinations
For Nearline 10 RAID, network and SNMP settings are set and stored on the RAID
controller module. For the RAID chassis with two controllers, each controller has its
own network settings and the RAID chassis exists as two entities on the control
network.
The RAID storage device is configured by default for the SNMP community name
“public”. If your site’s policies require using a different SNMP community name,
contact your Grass Valley representative.
To configure these settings, do the following:
1. Launch Storage Utility from the K2 System Configuration application as in the
previous procedure.
2. As prompted, wait while Storage Utility gathers system information, then Storage
File System Server
Configuration
Click
Launch Storage Manager
. Storage Utility opens.
On this page…
Do this…