Chapter 14 Administering and maintaining the K2 Storage System

• SNMP trap destinations

For the Level 3, 10, 20, or 30 RAID chassis, network and SNMP settings are set and
stored on the RAID controller. Therefore, if the RAID chassis has two controllers,
each controller must be configured separately, as in the following procedure.

1. In the K2 System Configuration application tree view, open the node for a K2

Media Server and select the

File System Server

node to open its property page. On

the property page click

Launch Storage Utility

. Storage Utility opens.You can now

configure the network settings on the controller connected to the selected K2
Media Server.

2. In the Storage Utility, right-click the icon for a RAID controller and select

Configuration | Network Properties

. The Network Settings dialog box opens.

3. In the Controller Slot Number field enter

0

and then press

Enter

. The settings from

controller 0 are loaded into the Controller Network Settings dialog box and are
available for you to modify.

4. Enter the control network IP address and other network settings.

5. You want SNMP trap messages go to the NetCentral server PC, so for SNMP

Configuration enter the IP address of the NetCentral server PC. You can also enter
IP addresses for other SNMP managers to which you want to send SNMP trap
messages.

6. If the RAID chassis has two controllers, in the Controller Slot Number field enter