Configuring the Level 30R storage system
Configuring the Level 30R storage system
Work through the topics in this section sequentially to do the initial configuration of
the Level 30R storage system.
•
“Prerequisites for initial configuration” on page 325
•
“Defining a new K2 Storage System” on page 326
•
“Configuring server A - Part 1” on page 328
•
“Configuring RAID” on page 330
•
“Creating a new file system” on page 336
•
“Configuring server A - Part 2” on page 338
•
“Configuring the redundant server” on page 341
•
“Configuring optional NH servers” on page 345
Prerequisites for initial configuration
Before beginning your initial configuration, make sure the devices of the K2 Storage
System meet the following prerequisites. Refer to sections earlier in this manual for
detailed information..
Devices
Prerequisite for Level 30R configuration
Control point PC
Ethernet cable connected
Control Point software installed
Control network IP address assigned
Network communication over the control network with all other K2
devices
Power on
Ethernet switch
Ethernet cables connected
Control network IP address assigned
VLANs set up
Trunks set up
Power on
K2 Media Server
Ethernet cables connected
Fibre Channel cable connected
Redundant servers connected by serial cable
Software installed, as from the factory, including QuickTime 7
Control network IP address assigned
Power on for all servers