June 25, 2009

Chapter 2 Installing the Level 10 Storage System

Refer to

“Prerequisites for initial configuration” on page 62

to confirm that the RAID

storage is ready for configuration.

Configuring RAID network and SNMP settings

Use the Storage Utility to configure the following settings for the Level 10 RAID
controller:

• IP address

• Subnet mask

• Gateway Address

• SNMP trap destinations

For L10 RAID, network and SNMP settings are set and stored on the RAID controller
module, so the combined RAID storage devices, including the optional Expansion
chassis, exist as a single entity on the control network.

The RAID storage device is configured by default for the SNMP community name
“public”. If your site’s policies require using a different SNMP community name,
contact your Grass Valley representative.

To configure these settings, do the following:

1. Launch Storage Utility from the K2 System Configuration application as in the

previous procedure.

2. As prompted, wait while Storage Utility gathers system information, then Storage

Utility opens.

3. In Storage Utility tree view, expand the node for the L10 RAID, right-click the icon

for a L10 RAID controller, and select

Configuration | Network Properties

.

The Controller Network Settings dialog box opens.