Preparing level 10r devices, Setting up the control point pc – Grass Valley K2 Storage System Instruction Manual v.3.3 User Manual
Page 83

June 25, 2009
K2 Storage System Instruction Manual
83
Preparing Level 10R devices
connected by a serial cable which supports the heartbeat signal required for automatic
system recovery (failover) features. Each GS K2 Media Server has redundant power
supplies.
The L10 RAID chassis has redundant RAID controllers to support the Fibre Channel
connections from the K2 Media Servers. The L10 RAID chassis is also connected to
the GigE control network, which is required for SNMP (NetCentral) monitoring.
On the L10 RAID chassis there are two RAID 1 RANKs (also know as LUNs) for
media file system metadata files and journal files. The remainder of the RAID storage
is RAID 5 or RAID 6 for media.
The K2 configuration control point PC is connected to the GigE control network. The
K2 System Configuration application runs on this PC for configuring the storage
system.
FTP/streaming traffic accesses the K2 Storage System via the FTP GigE port on K2
Media Servers. FTP/streaming traffic does not go to K2 Media Clients.
Description of K2 Storage Devices for more information. Also
“Design considerations for Ethernet switches” on page 559
.
Preparing Level 10R devices
Use the topics in this section to prepare each device so that it is ready to become part
of the Level 10R storage system.
•
“Setting up the Control Point PC”
•
“Setting up the Level 10R Gig E switch”
•
•
“Setting up the Level 10R K2 Media Server”
•
“Setting up the L10R RAID chassis”
•
“Preparing K2 Storage System clients”
Setting up the Control Point PC
To set up the K2 configuration Control Point PC, you have the following options:
• Use the Grass Valley Control Point PC that comes from the factory with software
pre-installed. This includes the K2 System Configuration application, remote
AppCenter, and NetCentral software. Refer to the K2 Media Client System Guide
for rack mount instructions.
• Use a PC that you own and install the required software.
For either option, you must do the following for the Control Point PC that runs the K2
System Configuration application:
• Assign a control network IP address to the PC. Refer to
“Networking tips” on
page 112
.
• Connect the PC to the GigE control network.
To use your own PC, you must additionally do the following: