Level 30 storage system power-off procedure – Grass Valley K2 Storage System Instruction Manual v.3.3 User Manual
Page 293
June 25, 2009
K2 Storage System Instruction Manual
293
Level 30 storage system power-off procedure
3. Shut down optional NH K2 Media Servers, if any.
4. On the primary RAID chassis controller, identify the RDY LED. It blinks at a rate
of 1 blink per second during normal operation.
5. Press and hold down the power button on the RAID controller.
6. Release the power button in about 5 seconds, when the RDY LED blinks more
quickly, at a rate of about 2 blinks per second. Do not hold down the power button
for longer than 15 seconds.
The power button on the RAID controller turns off power for the primary RAID
chassis and any connected Expansion chassis. Power-off normally occurs within
20 seconds and is indicated when LEDs other than those on the power supplies go
off and the fans stop rotating.
7. Wait for RAID power-off to complete before proceeding.
8. Power-off all Ethernet switches.